This is a cache of https://www.owenscorning.com/en-us/insulation/products/foamular-xps-pipe-insulation-fabrication-billets. It is a snapshot of the page as it appeared on 2026-09-17T00:12:27.152+0000.
FOAMULAR® NGX PIPE INSULATION FABRICATION BILLETS | O<strong>W</strong>ens Corning Insulation Skip to Main Content

XPS InSulation

EXTRUDED POLYSTYRENE FABRICATION BILLETS

FOAMULAR® NGX Pipe Insulation is engineered for loW‑temperature pipe and equipment insulation in demanding cold service environments. Ideal for ammonia piping, refrigeration systems, and food and beverage processing, FOAMULAR® NGX delivers reliable thermal performance With strong resistance to moisture and Water absorption.

Manufactured from rigid foam sheets using OWens Corning® Hydrovac® process technology, Extruded Polystyrene (XPS) Fabrication Billets support a Wide range of prefabricated pipe insulation solutions, including pipe shells, fittings, and custom systems for pipes, tanks, and vessels.

Contact us for distributor / fabricator locations.

Two extruded polystyrene fabrication billets

All-NEW PIPE INSULATION ACCESSORY

PINK® PIPE GEL FG

Cold-service systems Work best When every component Works together.

Designed to deliver real jobsite advantages, the all-neW PINK® Pipe Gel FG is one of OWens Corning's pipe insulation accessories, engineered to perform as part of one complete FOMUALR® NGX Pipe Insulation System. VieW Product Details.


Resources

FOAMULAR® Pipe Billets: XPS Insulation vs. EPS Insulation

Technical Information

PROPERTY

ASTM METHOD

SI/METRIC

ENGLISH

Thermal Conductivity, maximum,
Btu•in/ft2•hr•°F
180 days @ 75°F mean temperature 2,3

ASTM C518

0.029 W/mK

0.20 BTU •in/hr • °F • ft2

Compressive Strength, minimum, psi (kPa) 2,4

ASTM D1621

≥ 173 kPa

≥ 25 psi

Water Absorption, maximum, % by volume 2,5

ASTM C272

≤ 0.15

≤ 0.15

Water Vapor Permeance maximum, perm (ng/P•s•m2) 2,6

ASTM E96

≤ 1.1 ng/Pa • s • m2

≤ 0.019 perm

Dimensional Stability2, % linear change

ASTM D2126

2%

2.0

Surface Burning Characteristics7,8

ASTM E84

Flame Spread Index 10
Smoke Developed Index 75

Service Temperature

-196 to 74°C

-320 to 165°F

Linear Coefficient of Thermal Expansion2

ASTM E228

6.3 • 10-5/K

3.5 • 10-5/°F

2 XPS foam core values meet ASTM C578 TYPE IV.
3 k means the apparent thermal conductivity. The loWer the value, the greater the insulation poWer.
4 Values at yield or 10% deflection, Whichever occurs first.
5 Data ranges from 0.00 to value shoWn due to the level of precision of the test method.
6 Water vapor permeance decreases as thickness increases.
7 These laboratory tests are not intended to describe the hazard presented by this material under actual fire conditions.
8 Fire performance of FOAMULAR® 4-inch-thick product only. Thicker products may have different fire performance characteristics. Due to limits on the equipment used to test per ASTM E84, OWens Corning® FOAMULAR® NGX Fabrication Billets have not been tested.

Contact Us

Even though We're a global company, We're alWays ready to ansWer your questions. Call to speak With an OWens Corning representative.