Concrete Masonry Unit with EIFS and Fluid or Sheet AWB with Mineral Wool Continuous Insulation | Owens Corning Insulation
Skip to main content

EIFS (PM, hard coat) CMU Wall Mineral Wool CI with Fluid or Sheet AWB

Overview

This Enclosure Solutions Wall System includes a CMU structure with EIFS and mineral wool continuous insulation with fluid or sheet applied air and water resistive barrier. Complies with NFPA 285 (fire), ASTM E2357 (air), and ASTM E331 (water).

Get all the construction documentation you'll need, in a single click:

Model of CMU Wall EIFS (PM, hard coat) Mineral Wool CI with Fluid or Sheet AWB

Specifications and Literature

Products In This Solution


Additional Products

Sold Separately

  • CMU
  • Lath Drainage Plane
  • Lath Screws and Washers
  • Air and Water Barrier (AWB)
  • Air & Water Sealing Fasteners
  • EIFS System

Performance Attributes

Badge icon

Durability

Clipboard with check mark icon

Easy Installation

Recycling icon

Recycled Materials

Icon of house showing heat waves

Thermal Comfort

ASHRAE 90.1

ASHRAE Standard 90.1 requires Continuous Insulation (CI) be used for all commercial and some residential buildings in the United States. Continuous insulation is defined in 90.1 as “insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings. It is installed on the interior, exterior, or is integral to any opaque surface of the building envelope”.

ASHRAE 90.1

ASTM E2307

ASTM E2307 measures the ability of perimeter fire barrier systems to maintain a seal and prevent interior fire spread as the exterior wall assembly deflects and deforms during fire exposure. The ASTM E2307 test exposes the joint to fire from the room of fire origin and the exterior wall to fire from both the interior and the exterior as the fire plume exits the room of fire origin through a window opening. ASTM E 2307 determines the period of time that the perimeter fire containment system will limit flame penetration through the opening between the exterior wall assembly and the floor assembly.

 ASTM E2307

NFPA 285 Compliant

NFPA 285 is required in the International Building Code (IBC) in multiple situations. The NFPA 285 test is to determine that combustibles, when exposed to fire on the exterior face of the wall, do not spread flame over the surface or through the core of the otherwise non-combustible wall assembly.

NFPA 285 Compliant

Additional Attributes and Compliance

This wall assembly enclosure also meets the following codes and standards. Click a standard to learn more

Case Studies & Projects

Owens Corning® Enclosure Solutions deliver buildings that perform without compromising design. Take a look at a few key case studies below.

Ronald McDonald House

Ronald McDonald House

Toledo, OH

Owens Corning contributed building science expertise and donated a range of insulation products including FOAMULAR® XPS insulation which was used in the building’s enclosure.


Mission My Care Plus Leicester

Mission My Care Plus Leicester

Asheville, NC

Mission My Care Plus Leicester, used FOAMULAR® 250 Continuous Insulation and JointSealR® Foam Joint Tape in the construction of the three-story Medical Office Building.


Kent State College of Architecture

Kent State College of Architecture

Kent, OH

Kent State College of Architecture represents bold, contemporary building design. Easy-to-install FOAMULAR® 250 Continuous Insulation was incorporated in the Building Enclosure.