Installation Instructions
Step 1
Using a chalk line, mark out 1 inch on both sides of the ridge as a guide for cutting a slot in the top of the ridge.
VentSure® 4-Foot Strip with Weather PROtector®
VentSure® 4-Foot Strip Ridge Vents are designed for roofs with slopes of ³/12 to 16/12.
Intake at the eave vents should be equal or exceed that of the ridge vent being installed.
Center the vent over the opening that has been cut in the ridge, ensuring the vent sits flat on the roof. Also ensure that the alignment tabs are facing the opposite direction you will be installing the next piece of ridge vent. For cold weather installation leave a gap no bigger than ⅛ inch to allow for expansion. Gaps larger than ⅛ inch could lead to rain and snow entering the attic.
Nail hip and ridge shingles over the vent using nails long enough to meet the penetration requirements of the local building code and shingle manufacturer or use nails provided with the VentSure® ridge vent. For a clean look, extend the hip and ridge shingle to cover the alignment tabs or trim tabs off using a utility knife.
Cut slot 1 inch on both sides of ridge to within 6 inches of each end wall or hip intersection.
Cut slots 12 inches from chimney. Run ridge vent from end of roof to butt against chimney.
Saw slots to within 12 inches of ridge intersection points as shown. Install ridge vent completely across ridge on long side and butt ridge vent on the short run against the side of the long run.
NOTE: To prevent leakage and preserve aesthetic roof line, always leave at least 6 inches between ridge slot and end of ridge.
NOTE: The net free area of soffit ventilation should always be at least equal to or more than the net free area of the ridge ventilation.