Thermafiber® Crimped Backpan Perimeter Fire Containment System | Owens Corning Insulation
Skip to main content

Thermafiber® Crimped Backpan Perimeter Fire Containment System

Overview

Thermafiber® Crimped Backpan System simplifies installation and inspection by using a crimped backpan, eliminating extra reinforcement. It allows up to 3-inch displacement and provides up to 2-hours of fire protection -- tested and listed by Intertek®.

Thermafiber® Crimped Backpan System

Specifications and Literature

Products In This Solution


Additional Products

Sold Separately

  • Concrete Floor Slab
  • Vision Glass
  • Curtain Wall Anchors
  • Vertical Mullion
  • Min. 20 Ga. Galvanized Stell Crimped Backpan
  • Horizontal Transom

Partner Products



Performance Attributes

Clipboard with check mark icon

Easy Installation

Flame icon

Fire Protection

Acoustic

Acoustic Performance

thermal icon

Thermal Performance

ASTM E2307

ASTM E2307 measures the ability of perimeter fire barrier systems to maintain a seal and prevent interior fire spread as the exterior wall assembly deflects and deforms during fire exposure. The ASTM E2307 test exposes the joint to fire from the room of fire origin and the exterior wall to fire from both the interior and the exterior as the fire plume exits the room of fire origin through a window opening. ASTM E 2307 determines the period of time that the perimeter fire containment system will limit flame penetration through the opening between the exterior wall assembly and the floor assembly.

Fire depicting ASTM E2307

INTERTEK® Approved Design Per ASTM E2307

Intertek is a leading provider of testing, inspection, and certification services worldwide. They offer a wide range of services, including testing for fire safety compliance. Intertek helps ensure that products and systems comply with relevant industry standards and regulations, including ASTM E2307. This test is critical in determining the fire safety of exterior wall assemblies and preventing the spread of flames. Design documents: 2-Hour F Rating Listing: TFI/BPF 120-15 | 3-Hour F Rating Listing: TFI/BPF 180-07

Zoomed out view showing many office spaces in a building with Intertek logo overlayed

Contact Us

Even though we’re a global company, we’re always ready to answer your technical support questions regarding our products and solutions. Email to speak with our GETTECH team.