Installation Instructions
Step 1
Using a chalk line, mark out 1 inch on both sides of the ridge as a guide for cutting a slot in the top of the ridge.
Storage Preferences
VentSure® 4-Foot Strip with Weather PROtector®
VentSure® 4-Foot Strip Ridge Vents are designed for roofs with slopes of ³/12 to 16/12.
Intake at the eave vents should be equal or exceed that of the ridge vent being installed.
Using a chalk line, mark out 1 inch on both sides of the ridge as a guide for cutting a slot in the top of the ridge.
Start and end 6 inches away from the rake edge of the roof, cut a slot using a circular saw with the blade set at a depth to cut through the wood sheathing only. Remove the sheathing debris from slot.
Center the vent over the opening that has been cut in the ridge, ensuring the vent sits flat on the roof. Also ensure that the alignment tabs are facing the opposite direction you will be installing the next piece of ridge vent. For cold weather installation leave a gap no bigger than ⅛ inch to allow for expansion. Gaps larger than ⅛ inch could lead to rain and snow entering the attic.
As you install the vents ensure each vent is aligned, then nail in place using the nail holes marked on each vent.
Using a utility knife cut the final piece to a length long enough so that it is flush with the edge of the roof. Connect making sure that the built-in end caps are exposed and nail in place.
Nail hip and ridge shingles over the vent using nails long enough to meet the penetration requirements of the local building code and shingle manufacturer or use nails provided with the VentSure® ridge vent. For a clean look, extend the hip and ridge shingle to cover the alignment tabs or trim tabs off using a utility knife.
Cut slot 1 inch on both sides of ridge to within 6 inches of each end wall or hip intersection.
Cut slots 12 inches from chimney. Run ridge vent from end of roof to butt against chimney.
Saw slots to within 12 inches of ridge intersection points as shown. Install ridge vent completely across ridge on long side and butt ridge vent on the short run against the side of the long run.
NOTE: To prevent leakage and preserve aesthetic roof line, always leave at least 6 inches between ridge slot and end of ridge.
LIMITED WARRANTY This product is covered by a Limited Warranty which is available by calling 1-800-GET-PINK® or visiting www.owenscorning.com.