Overview
Overview
This Enclosure Solutions Wall System includes a steel stud structure with architectural metal panel, exterior gypsum sheathing, mineral wool ci insulation with fluid or sheet applied AWB, & mineral wool batt insulation. Complies with NFPA 285 (fire), ASTM E2357 (air), & ASTM E331 (water).
Get all the construction documentation you'll need, in a single click:
Specifications and Literature
Products In This Solution
Additional Products
Additional Products
Sold Separately
- Interior Gypsum Board
- Galvanized Steel Studs
- Exterior Gypsum Sheathing
- Air & Water Sealing Fasteners
- Air & Water Barrier (AWB)
- Cladding Attachment System
- Architectural Metal Panels (ACM, MCM)
Performance Attributes
Durability
Fire Resistance
Sound Reduction
Thermal Comfort
ASHRAE 90.1
ASHRAE 90.1
ASHRAE Standard 90.1 requires Continuous Insulation (CI) be used for all commercial and some residential buildings in the United States. Continuous insulation is defined in 90.1 as “insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings. It is installed on the interior, exterior, or is integral to any opaque surface of the building envelope”.
ASTM E2307
ASTM E2307
ASTM E2307 measures the ability of perimeter fire barrier systems to maintain a seal and prevent interior fire spread as the exterior wall assembly deflects and deforms during fire exposure. The ASTM E2307 test exposes the joint to fire from the room of fire origin and the exterior wall to fire from both the interior and the exterior as the fire plume exits the room of fire origin through a window opening. ASTM E 2307 determines the period of time that the perimeter fire containment system will limit flame penetration through the opening between the exterior wall assembly and the floor assembly.
NFPA 285 Compliant
NFPA 285 Compliant
NFPA 285 is required in the International Building Code (IBC) in multiple situations. The NFPA 285 test is to determine that combustibles, when exposed to fire on the exterior face of the wall, do not spread flame over the surface or through the core of the otherwise non-combustible wall assembly.
Additional Attributes and Compliance
Additional Attributes and Compliance
This wall assembly enclosure also meets the following codes and standards. Click a standard to learn more
Drawings
Bim Objects
Bim Objects
Construction Details including BIM objects and CAD drawing files for Steel Stud Enclosure Solutions Wall Systems are available for download below.
OWENS CORNING ENCLOSURE SOLUTIONS STEEL STUD WALLS BIM
RVT 4.24 MB
CAD Files
CAD Files
STEEL STUD WALLTHERMAFIBER® RAINBARRIER 45 CI
Perimeter Fire Containment
DWG 138.76 KB
STEEL STUD WALLTHERMAFIBER® RAINBARRIER 45 CI
Foundation Transition
DWG 120.83 KB
STEEL STUD SILLTHERMAFIBER® RAINBARRIER 45 CI
Wall Section
DWG 136.86 KB
STEEL STUD WALLTHERMAFIBER® RAINBARRIER 45 CI
Gravel Stop/Roof Transition
DWG 115.79 KB
STEEL STUD WALLTHERMAFIBER® RAINBARRIER 45 CI
Parapet/Roof Transition
DWG 114.52 KB
STEEL STUD JAMBTHERMAFIBER® RAINBARRIER 45 CI
Wall Section
DWG 135.59 KB
STEEL STUD HEADTHERMAFIBER® RAINBARRIER 45 CI
Wall Section
DWG 119.58 KB
STEEL STUD WALLTHERMAFIBER® RAINBARRIER 45 CI
Wall Section
DWG 113.67 KB
STEEL STUD WALLVERTICAL TRANSITION
Masonry with Thermafiber RainBarrier 45 to Panel System with Thermafiber RainBarrier 45 Mineral Wool
DWG 89.12 KB
STEEL STUD WALLHORIZONTAL TRANSITION
Panel System with Thermafiber RainBarrier 45 Mineral Wool to Masonry with Thermafiber RainBarrier 45 Mineral Wool
DWG 96.7 KB
STEEL STUD WALLVERTICAL TRANSITION
Panel System with Thermafiber RainBarrier 45 Mineral Wool to Masonry with Thermafiber RainBarrier 45 Mineral Wool
DWG 89.65 KB
STEEL STUD WALLVERTICAL TRANSITION
Masonry with Foamular 250 XPS to Panel System Thermafiber RainBarrier 45 Mineral Wool
DWG 80.7 KB
STEEL STUD WALLHORIZONTAL TRANSITION
Panel System with Thermafiber RainBarrier 45 Mineral Wool to Masonry with Foamular 250 XPS
DWG 75.33 KB
Case Studies & Projects
Owens Corning® Enclosure Solutions deliver buildings that perform without compromising design. Take a look at a few key case studies below.
Ann Arbor, MI
Owens Corning® Thermafiber RainBarrier 45 mineral wool insulation was used in the masonry cavity wall construction to minimize the loss of hot and cold and maximize energy efficiency, thermal insulation, fire protection and accoustical control.
Contact Us
Contact Us
Even though we’re a global company, we’re always ready to answer your technical support questions regarding our products and solutions. Email to speak with our GETTECH team.