Steel Stud Architectural Metal (ACM, MCM) Wall Enclosure

with Thermafiber® Mineral Wool CI Insulation with Fluid or Sheet AWB

Overview

This Enclosure Solutions Wall System includes a steel stud structure with architectural metal panel, exterior gypsum sheathing, mineral wool ci insulation with fluid or sheet applied AWB, & mineral wool batt insulation. Complies with NFPA 285 (fire), ASTM E2357 (air), & ASTM E331 (water).

Get all the construction documentation you'll need, in a single click:

Steel Stud with Architectural Metal Panel

Specifications and Literature

Products In This Solution


Additional Products

Sold Separately

  • Interior Gypsum Board
  • Galvanized Steel Studs
  • Exterior Gypsum Sheathing
  • Air & Water Sealing Fasteners
  • Air & Water Barrier (AWB)
  • Cladding Attachment System
  • Architectural Metal Panels (ACM, MCM)

Performance Attributes

Durability

Durability

Fire Resistance

Fire Resistance

Sound Reduction

Sound Reduction

Thermal Comfort

Thermal Comfort

ASHRAE 90.1

ASHRAE Standard 90.1 requires Continuous Insulation (CI) be used for all commercial and some residential buildings in the United States. Continuous insulation is defined in 90.1 as “insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings. It is installed on the interior, exterior, or is integral to any opaque surface of the building envelope”.

ASHRAE 90.1

ASTM E2307

ASTM E2307 measures the ability of perimeter fire barrier systems to maintain a seal and prevent interior fire spread as the exterior wall assembly deflects and deforms during fire exposure. The ASTM E2307 test exposes the joint to fire from the room of fire origin and the exterior wall to fire from both the interior and the exterior as the fire plume exits the room of fire origin through a window opening. ASTM E 2307 determines the period of time that the perimeter fire containment system will limit flame penetration through the opening between the exterior wall assembly and the floor assembly.

 ASTM E2307

NFPA 285 Compliant

NFPA 285 is required in the International Building Code (IBC) in multiple situations. The NFPA 285 test is to determine that combustibles, when exposed to fire on the exterior face of the wall, do not spread flame over the surface or through the core of the otherwise non-combustible wall assembly.

NFPA 285 Compliant

Additional Attributes and Compliance

This wall assembly enclosure also meets the following codes and standards. Click a standard to learn more

Drawings

Bim Objects

Construction Details including BIM objects and CAD drawing files for Steel Stud Enclosure Solutions Wall Systems are available for download below.

OWENS CORNING ENCLOSURE SOLUTIONS STEEL STUD WALLS BIM

OWENS CORNING ENCLOSURE SOLUTIONS STEEL STUD WALLS BIM

RVT 4.24 MB

CAD Files

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD WALLTHERMAFIBER® RAINBARRIER 45 CI

Perimeter Fire Containment


DWG 138.76 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD WALLTHERMAFIBER® RAINBARRIER 45 CI

Foundation Transition


DWG 120.83 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD SILLTHERMAFIBER® RAINBARRIER 45 CI

Wall Section


DWG 136.86 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD WALLTHERMAFIBER® RAINBARRIER 45 CI

Gravel Stop/Roof Transition


DWG 115.79 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD WALLTHERMAFIBER® RAINBARRIER 45 CI

Parapet/Roof Transition


DWG 114.52 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD JAMBTHERMAFIBER® RAINBARRIER 45 CI

Wall Section


DWG 135.59 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD HEADTHERMAFIBER® RAINBARRIER 45 CI

Wall Section


DWG 119.58 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD WALLTHERMAFIBER® RAINBARRIER 45 CI

Wall Section


DWG 113.67 KB

VERTICAL TRANSITION

STEEL STUD WALLVERTICAL TRANSITION

Masonry with Thermafiber RainBarrier 45 to Panel System with Thermafiber RainBarrier 45 Mineral Wool


DWG 89.12 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD WALLHORIZONTAL TRANSITION

Panel System with Thermafiber RainBarrier 45 Mineral Wool to Masonry with Thermafiber RainBarrier 45 Mineral Wool


DWG 96.7 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD WALLVERTICAL TRANSITION

Panel System with Thermafiber RainBarrier 45 Mineral Wool to Masonry with Thermafiber RainBarrier 45 Mineral Wool


DWG 89.65 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD WALLVERTICAL TRANSITION

Masonry with Foamular 250 XPS to Panel System Thermafiber RainBarrier 45 Mineral Wool


DWG 80.7 KB

THERMAFIBER® RAINBARRIER 45 CI

STEEL STUD WALLHORIZONTAL TRANSITION

Panel System with Thermafiber RainBarrier 45 Mineral Wool to Masonry with Foamular 250 XPS


DWG 75.33 KB

Case Studies & Projects

Owens Corning® Enclosure Solutions deliver buildings that perform without compromising design. Take a look at a few key case studies below.

Ann Arbor, MI

Ann Arbor, MI

Owens Corning® Thermafiber RainBarrier 45 mineral wool insulation was used in the masonry cavity wall construction to minimize the loss of hot and cold and maximize energy efficiency, thermal insulation, fire protection and accoustical control.

Contact Us

Even though we’re a global company, we’re always ready to answer your technical support questions regarding our products and solutions. Email to speak with our GETTECH team.