Steel Stud Wall Terra Cotta Veneer

Mineral Wool with Black Facer as CI with Fluid or Sheet AWB

Overview

This Wall System includes a steel stud structure with terra cotta veneer, exterior gypsum sheathing, mineral wool CI with black facer, & mineral wool batt. By selecting correct components, it complies with ASTM E119(fire), ASTM E2357(air), & ASTM E331(water).

Get all the construction documentation you'll need, in a single click:

Specifications and Literature

Products In This Solution

Thermafiber® RainBarrier® Dark Mineral Wool Insulation

Thermafiber® Fire and Sound Guard Plus® Mineral Wool Insulation

Thermafiber® Safing Insulation

Additional Products 

Sold Separately

  • Interior Gypsum Board
  • Galvanized Steel Studs
  • Exterior Gypsum Sheathing
  • UV Resistant Air & Water Barrier (AWB)
  • Air & Water Sealing Fasteners
  • Cladding Attachment System
  • Open Joint Terra Cotta System


Performance Attributes

ASHRAE 90.1

ASHRAE Standard 90.1 requires Continuous Insulation (CI) be used for all commercial and some residential buildings in the United States. Continuous insulation is defined in 90.1 as “insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings. It is installed on the interior, exterior, or is integral to any opaque surface of the building envelope”.

ASTM E2307

ASTM E2307 measures the ability of perimeter fire barrier systems to maintain a seal and prevent interior fire spread as the exterior wall assembly deflects and deforms during fire exposure. The ASTM E2307 test exposes the joint to fire from the room of fire origin and the exterior wall to fire from both the interior and the exterior as the fire plume exits the room of fire origin through a window opening. ASTM E 2307 determines the period of time that the perimeter fire containment system will limit flame penetration through the opening between the exterior wall assembly and the floor assembly.

ASTM E119

Drawings

Case Studies & Projects

Contact Us

Even though we're a global company, we're always ready to answer your questions. Call to speak with an Owens Corning representative.