Overview
Overview
This Enclosure Solutions Wall System includes a steel stud structure with stucco veneer, exterior gypsum sheathing, ccSPF continuous insulation as the AWB, & mineral wool batt. By selecting correct components, it complies with NFPA 285(fire), ASTM E2357(air), & ASTM E331(water).
Get all the construction documentation you'll need in a single click:
Specifications and Literature
Products In This Solution
Natural Polymers® Natural-Therm® Pro
FlashSealR® Foam Flashing Tape
JointSealR® Foam Joint Tape
FluidSealR® Liquid Flashing
Thermafiber® Fire and Sound Guard Plus® Mineral Wool insulation
Thermafiber® Safing insulation
Additional Products
Additional Products
Sold Separately
- Interior Gypsum Board
- Galvanized Steel Studs
- Exterior Gypsum Sheathing
- Air & Water Sealing Fasteners
- Lath Drainage Plane
- Lath Screws & Washers
- Stucco System
Performance Attributes
Durability
Easy Installation
Recycled Materials
Thermal Comfort
ASHRAE 90.1
ASHRAE 90.1
ASHRAE Standard 90.1 requires Continuous insulation (CI) be used for all commercial and some residential buildings in the United States. Continuous insulation is defined in 90.1 as “insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings. It is installed on the interior, exterior, or is integral to any opaque surface of the building envelope”.
NFPA 285 Compliant
NFPA 285 Compliant
NFPA 285 is required in the International Building Code (IBC) in multiple situations. The NFPA 285 test is to determine that combustibles, when exposed to fire on the exterior face of the wall, do not spread flame over the surface or through the core of the otherwise non-combustible wall assembly.