This is a cache of https://www.owenscorning.com/en-us/insulation/residential/spray-foam/natural-polymers-connect/density-calculator. It is a snapshot of the page as it appeared on 2026-01-31T17:10:29.144+0000.
NP Connect Density Calculator | Owens Corning
Skip to main content

Choose your Calculation Method

Spray Foam Density Calculator

  • The displacement method is only suitable for medium density (closed cell) products.
  • The caliper method can be used for both closed and open cell

What you need

  • 1000 ml graduated cylinder

    1000 ml graduated cylinder

  • Gram scale

    Gram scale

  • Sharp knife to prepare a sample

    Sharp knife to prepare a sample

Collect a Sample

  • Sample should weigh 5.5 - 10.0g
  • Trim to easily fit the graduated cylinder
  • Should not have any internal or external “skins” or knit lines

Instructions

  1. Prepare a 5.5-10 gram sample with no skins. It should fit easily within the graduated cylinder
  2. Weigh the sample and enter the value.
  3. Fill the cylinder 2/3 with water and enter the initial water level.
  4. Completely submerge the sample under the water level and enter the submerged value.
Displacement Method
Calculate
Initial levelSubmerged levelVolumeWeightDensity
mlmlmlGramsPFC(Kg/m³)
------
Initial level-
Submerged level-
Volume-
Weight-
Density- -

THIS TOOL PROVIDES ESTIMATES ONLY AND IS INTENDED FOR USER CONVENIENCE. NP/OC makes no representations and is not responsible for implications of product performance or yield promises based on tool outputs. For actual measurements, standardized test methods like ASTM D1622 are the appropriate means of quantifying foam density.

ProductTarget Density (lbs/cu.ft.)*
0.5lb open cell<0.55
NT Light<0.45
NT 2.0 HFO1.85-2.15
NT Zero1.6-1.9

*Approximate values, if needed run multiple samples and average for better estimations.

Contact Us

We’re always ready to answer your questions. Call to speak with a Natural Polymers representative.