This is a cache of https://www.owenscorning.com/en-us/insulation/products/foamular-insul-pink. It is a snapshot of the page as it appeared on 2026-02-06T03:00:41.506+0000.
<strong>foamular</strong>® INSULPINK® | Owens Corning Insulation
Skip to main content

foamular® INSULPINK® extruded polystyrene (XPS) insulation is extremely light-weight for easy handling and is used to insulate the interiors of basements or other concrete or block walls.

Certifications

Energy Star

Energy Star

SCS Recycled Content - Average 20%

SCS Recycled Content - Average 20%

UL Greenguard EPD

UL Greenguard EPD

UL Greenguard Gold

UL Greenguard Gold

Performance Attributes

Moisture Resistance icon

Moisture Resistance

Durability icon

Durability

Easy Installation icon

Easy Installation

Technical Information

PROPERTY1

TEST METHOD2

VALUE

Thermal Resistance3, R-Value (180 day) minimum,
hr·ft2·°F/Btu (RSI, °C·m2/W)
@ 75°F (24°C) mean temperature

ASTM C518
1½" Thickness7.5 (1.32)
@ 40°F (4.4°C) mean temperature
1½" Thickness8.1 (1.43)

Long Term Thermal Resistance, LTTR-Value3, minimum
hr·ft2·°F/Btu (RSI, °C·2/W)
@ 75°F (24°C) mean temperature

CAN/ULC S770-03
1½" Thickness7.8 (1.37)

Compressive Strength4, minimum psi (kPa)

ASTM D162115 (103)

Flexural Strength5, minimum psi (kPa)

ASTM C20360 (414)

Water Absorption6, maximum % by volume

ASTM C2720.10

Water Vapor Permeance7, maximum perm (ng/Pa·s·m2)

ASTM E961.5 (86)
Dimensional Stability, maximum % linear changeASTM D21262.0

Flame Spread8, 9

ASTM E845

Smoke Developed8, 9, 10

ASTM E8445-175

Oxygen Index8, minimum % by volume

ASTM D286324
Service Temperature, maximum °F (°C)165 (74)
Linear Coefficient of Thermal Expansion, in/in/°F (m/m°C)ASTM E228

3.5 x 10-5 (6.3 x 10-5)

  1. Properties shown are representative values for 1" thick material, unless otherwise specified.
  2. Modified as required to meet ASTM C578
  3. R means the resistance to heat flow; the higher the value, the greater the insulation power. This insulation must be installed properly to get the marked R-value. Follow the manufacturer’s instructions carefully. If a manufacturer’s fact sheet is not provided with the material shipment, request this and review it carefully. R-values vary depending on many factors including the mean temperature at which the test is conducted, and the age of the sample at the time of testing. Because rigid foam plastic insulation products are not all aged in accordance with the same standards, it is useful to publish comparison R-value data. The R-value for foamular® XPS Insulation is provided from testing at two mean temperatures, 40ºF and 75ºF, and from two aging (conditioning) techniques, 180 day realtime aged (as mandated by ASTM C578) and a method of accelerated aging sometimes called “Long Term Thermal Resistance” (LTTR) per CAN/ULC S770-03. The R-value at 180 day real-time age and 75ºF mean temperature is commonly used to compare products and is the value printed on the product.
  4. Values at yield or 10% deflection, whichever occurs first.
  5. Value at yield or 5%, whichever occurs first.
  6. Data ranges from 0.00 to value shown due to the level of precision of the test method.
  7. Water vapor permeance decreases as thickness increases.
  8. These laboratory tests are not intended to describe the hazards presented by this material under actual fire conditions.
  9. Data from Underwriters Laboratories Inc.® classified. See Classification Certificate U-197.
  10. ASTM E84 is thickness-dependent, therefore a range of values is given.

Applications

  • Walls

eBooks & Guides

Contact Us