Thermafiber® SAFB™ (Sound Attenuation Fire Blankets) are mineral wool batts designed to provide acoustical control and fire protection in many UL® fire-rated wall and floor-ceiling assemblies. These products are non-combustible, moisture resistant, non-corrosive, non-deteriorating, mildew-resistant, and vermin-resistant. SAFB™ resists temperatures over 1,093ºC (2,000ºF) and can add points to STC for walls and floor-ceiling assemblies. SAFB™ can be installed in both steel stud and wood-framed construction.
Thermafiber® SAFB™ (Sound Attenuation Fire Blanket)
Features
- Exceptional sound and noise absorption
- Adds STC value to wall and floor-ceiling assemblies
- Provides fire containment in rated assemblies
- Fire-resistant to temperatures above 1,093ºC (2,000ºF)
- See UL file R4739 for fire rated assembly listings
- Minimum 70% recycled content
- Mold-resistant1
- Contributes to credits in several green building programs, such as LEED® and Green Globes®
Standards, Codes Compliance
- CAN/ULC-S702.1, Standard for Mineral Fiber Thermal Insulation for Buildings2
- NFPA 101, Class A-rated interior finish
- Fire Rated Design
- ULC Classification Code: BZJZC
- UL Classification Code: BZJZ
Installation
- Interior Stud Cavity – Friction-fit SAFB™ securely between studs. Butt ends of blankets closely together and fill all voids.
- Creased SAFB™ – Using SAFB™ 25 mm (1") wider than regular blankets, bow the blankets slightly to fit into stud cavity. Slit the blankets vertically 25 mm (1") deep with a utility knife down the center.
- Floor-Ceiling – Friction-fit SAFB™ securely between floor joints.
- Ceiling Overlayment – Lay SAFB™ over ceiling panels, extending 1219 mm (48") beyond all partitions. Tightly fit around all hangers, obstructions, and penetrations.
Certifications and Sustainable Features
- Verified by ICC-ES to contain a minimum of 70% recycled content. See ICC-ES Evaluation Report VAR-1025 at icc-es.org.
- Environmental Product Declaration (EPD) has been certified by UL Environment. For more information, visit ul.com/epd.
- SAFB™ products have a published Health Product Declaration (HPD).
Specifications & Literature
Technical Information
Performance Criteria
PROPERTY | VALUE | TEST METHOD |
|---|---|---|
COMPLIANCE | CCMC Evaluation Listing No. 14059-L | CCMC |
Additional Performance Information
PROPERTY | VALUE | Test Method | |||||||
|---|---|---|---|---|---|---|---|---|---|
DENSITY | 40 kg/m³ (2.5 lbs/ft³) |
| |||||||
SAFB™ product < 38 mm (1.5"), 64 kg/m³ (4.0 lbs/ft³) | |||||||||
FIRE | Non-Combustible | CAN/ULC-S114 | |||||||
Non-Combustible as defined per NFPA Standard 220 | ASTM E136 | ||||||||
Smoulder Resistance Mean Mass Loss ≤ 0.02% | CAN/ULC-S129 | ||||||||
Flame Spread 0; Smoke Developed 0 | CAN/ULC-S102 | ||||||||
Flame Spread 0; Smoke Developed 0 | ASTM E84 | ||||||||
MOISTURE | Moisture Absorption <1% by volume | ASTM C1104 | |||||||
Fungi Resistance - Pass | ASTM C1338 | ||||||||
CORROSION | Stress Corrosion - Austenitic Stainless Steel - Pass | ASTM C795 | |||||||
Steel, Aluminum, Copper - Type 1 | ASTM C665 | ||||||||
ACOUSTIC 40 kg/m3 (2.5 pcf) | Thickness | 125 | 250 | 500 | 1000 | 2000 | 4000 | NRC |
|
51 mm (2") | 0.34 | 0.61 | 1.07 | 1.09 | 1.07 | 1.10 | 0.95 | ||
76 mm (3") | 0.51 | 0.99 | 1.18 | 1.03 | 0.99 | 0.96 | 1.05 | ||
102 mm (4") | 0.83 | 1.19 | 1.27 | 1.12 | 1.12 | 1.13 | 1.20 | ||
152 mm (6") | 1.37 | 1.32 | 1.23 | 1.16 | 1.12 | 1.12 | 1.20 | ||
Availability
PRODUCT | AVAILABLE THICKNESS IN 13 mm (1/2") INCREMENTS | STANDARD DEMENSIONS4,5 |
|---|---|---|
SAFB™ 2.5 | 38 mm - 178 mm (1.5" - 7") | 406 mm x 1219 mm (16" x 48"), |
SAFB™ 4.0 | 25 mm (1") | 406 mm x 1219 mm (16" x 48"), |
Tolerances | +6 mm (¼"), - 3 mm (-⅛") | Width: -0 +6 mm (¼"), |
5 Custom sizes are available upon request.
Environmental and Sustainability
Owens Corning is a worldwide leader in building material systems, insulation, and composite solutions, delivering a broad range of high-quality products and services.
Owens Corning is committed to driving sustainability by delivering solutions, transforming markets, and enhancing lives. More information can be found at owenscorning.ca or owenscorninglibrary.ca.
Technical Services Available
For Canadian Technical inquiries, please contact our technical team at owenscorning.ca/contacttech.
Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient’s sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for, the accuracy or reliability of data associated with particular uses of any product described herein. Owens Corning reserves the right to modify this document without prior notice.
For additional information, refer to the Safe Use Instruction Sheet (SUIS) found in the SDS Database via sds.owenscorning.com.
Applications
- Ceilings
- Floors
- Interior Acoustics
- Interior Acoustics > Interior Walls
- Walls