Highly Durable and Moisture Resistant

WHY CHOOSE FOAM BOARD INSULATION?

Owens Corning® FOAMULAR® NGX® EDGELOCK® is high-strength XPS insulation designed for use in engineered applications requiring additional load-bearing capabilities. FOAMULAR® NGX® EDGELOCK® is a patented XPS design that interlocks boards together, preventing thermal breaks.

Workers laying down Foamular GEO high-strength XPS insulation

FOAMULAR® NGX® High-Performance XPS Insulation

Owens Corning® FOAMULAR® NGX® insulation offers all the performance and ease-of-use you expect from Owens Corning® FOAMULAR® insulation with industry-leading sustainability. Learn how FOAMULAR® NGX® meets the new environmental regulations for Canada and a growing list of US states.

Performance Attributes

80%+ Reduction in GWP

Eliminates HFC 134a

Durability icon

Durability

Easy to Install icon

Easy to Install

Moisture Resistance icon

Moisture Resistance

Recycled Materials icon

Recycled Materials

Technical Information

Physical Properties1

Property

Test Method2

250

4006001000

Thermal Resistance, R-Value (180 days) minimum, hr•ft2•°F/Btu (RSI, °C•m2/W)
@ 75°F (24°C) mean temperature

ASTM C518

5.0 (0.88)

5.0 (0.88)

5.0 (0.88)5.0 (0.88)

@ 40°F (4.4°C) mean temperature

5.4 (0.95)

5.4 (0.95)

5.4 (0.95)

5.4 (0.95)

@ 25°F (-3.9°C) mean temperature

5.6 (0.99)

5.6 (0.99)

5.6 (0.99)

5.6 (0.99)

Long Term Thermal Resistance, LTTR-Value3, minimum hr•ft2•°F/Btu (RSI, °C•m2/W)
@ 75°F (24°C) mean temperature

CAN/ULC S770-03

5.0 (0.88)

5.0 (0.88)

5.0 (0.88)5.0 (0.88)

Compressive Strength4, minimum psi (kPa)

ASTM D1621

25
(172)

40 (276)60 (414)100 (689)

Flexural Strength5, minimum psi (kPa)

ASTM C203

50
(345)

90 (621)120 (828)150 (1035)

Water Absorption6, maximum % by volume

ASTM C272

0.3

0.30.30.3

Water Vapor Permeance7, maximum perm (ng/Pa•s•m2)

ASTM E96

1.5 (86)

1.1 (63)1.1 (63)1.1 (63)

Dimensional  Stability, maximum % linear change 

ASTM D2126

2.0

2.02.02.0

Flame Spread8, 9

ASTM E84

10

101010

Smoke Developed8, 9

ASTM E84

175

175175175

Oxygen Index8, minimum % by volume

ASTM D2863

24

242424
Service Temperature, maximum °F (°C)-

165
(74)

165 (74)165 (74)

165
(74)

Linear Coefficient of Thermal Expansion,
in/in/°F (m/m/°C)

ASTM E228

3.5 x 10-5 (6.3 x 10-5)

1. Properties shown are representative values for 1" thick material, unless otherwise specified.
2. Modified as required to meet ASTM C578.
3. R means the resistance to heat flow; the higher the value, the greater the insulation power. This insulation must be installed properly to get the marked R-value. Follow the manufacturer’s instructions carefully. If a manufacturer’s fact sheet is not provided with the material shipment, request this and review it carefully. R-values vary depending on many factors including the mean temperature at which the test is conducted, and the age of the sample at the time of testing. Because rigid foam plastic insulation products are not all aged in accordance with the same standards, it is useful to publish comparison R-value data. The R-value for FOAMULAR® NGX® XPS Insulation is provided from testing at mean temperatures of: -4°C (25oF), 4.4°C (40°F), and 24°C (75°F) and aging techniques of 180-day real time aged (as mandated by ASTM C578) and accelerated aging “Long-Term Thermal Resistance” (LTTR) per CAN/ULC S770-03. The R-value at 180-day real-time age and 75°F mean temperature is commonly used to compare products and is the value printed on the product.
4. Values at yield or 5% deflection, whichever occurs first.
5. Properties shown are representative values for 2" thick material, unless otherwise specified. Value at yield or 5%, whichever occurs first.
6. Data ranges from 0.00 to value shown due to the level of precision of the test method.
7. Water vapor permeance decreases as thickness increases.
8. These laboratory tests are not intended to describe the hazards presented by this material under actual fire conditions.
9. Data from Underwriters Laboratories Inc.® classified. See Classification Certificate U-197.

Applications